Komatsu — CHECK, CLEAN AND REPLACE AIR CLEANER ELEMENT

MAINTENANCE PROCEDURE MAINTENANCE NOTICE Never remove the inner element. It will allow dirt to enter and cause failure of the engine. Do not use a screwdriver or other tool. 3. After removing the outer element, cover the air connector inside the air cleaner body with a clean cloth or tape to prevent dirt or dust from entering. 4. Wipe off or brush off the dirt stuck to cover (3) and the inside of the air cleaner body. 5. Remove any dirt or dust that is accumulated to evacuator valve (4) installed to cover (3). 6.

Direct dry compressed air (less than 0.69MPa (7kgf/cm 2 , 99.4PSI)) to the outer element from inside along its folds, then direct it from outside along its folds and again from inside. 1) Remove one seal from the element whenever the element has been cleaned. 2) Replace the outer element which has been cleaned 5 times repeatedly or used throughout a year. Replace the inner element at the same time. 4-22