Komatsu — CLEAN INSIDE OF COOLING SYSTEM

MAINTENANCE PROCEDURE MAINTENANCE CLEAN INSIDE OF COOLING SYSTEM WARNING Immediately after the engine is stopped, the coolant is at a high temperature and the radiator is under high internal pressure. If the cap is removed to drain the coolant in this condition, there is a hazard of burns. Wait for the tem- perature to go down, then turn the cap slowly to release the pressure before removing it. Cleaning is carried out with the engine running. When standing up or leaving the operator's seat, set the safety lock lever to the LOCK position. For details of starting the engine, see "BEFORE STARTING ENGINE (PAGE 3-57)" and "STARTING ENGINE (PAGE 3-70)" in the OPERATION section.

There is danger of touching the fan if the undercover is left removed. Never enter behind the machine when the engine is running. Clean the inside of the cooling system, change the coolant and replace the corrosion resistor agent KI according to the table below. Stop the machine on level ground when cleaning or changing the coolant. Use a permanent type of antifreeze. If, for some reason, it is impossible to use permanent type antifreeze, use an antifreeze containing ethylene glycol. Super Coolant (AF- NAL ) has an anti-corrosion effect as well as an antifreeze effect.

The ratio of antifreeze to water depends on the ambient temperature, but to obtain the corrosion resistance effect, a minimum ratio of 30% by volume is necessary. In areas where the water is hard, always add Komatsu genuine corrosion resistor agent KI. One packet of corro- sion resistor agent contains 100g (0.22 lb). The standard density of the mixture should be 7g/liters (0.065 oz/US gal). When deciding the ratio of antifreeze to water, check the lowest temperature in the past, and decide from the mix- ing rate table given below. It is actually better to estimate a temperature about 10°C (50°F) lower when deciding the mixing rate.

4-26 Kind of coolant Cleaning inside of cooling system and changing coolant Adding corrosion resistor agent KI Permanent type anti- freeze (All season type) Every year (autumn)or every 2000 hours whichever comes first Every 1000 hours and when cleaning the inside of the cooling system and when changine cool- ant. Nom permanent type antifreeze containing ethylene glycol (winter, one season type) Every 6 months (spring, autumn) (Drain antifreeze in spring, add antifreeze in autumn) When not using anti- freeze Every 6 months or every 1000 hours whichever comes first