MAINTENANCE PROCEDURE MAINTENANCE 2. If the electrolyte level is below the midway point between the U.L and L.L lines, remove cap (1) and add distilled water to the U.L line. REMARK If distilled water is added to above the U.L line, use a pipette to lower the level to the U.L line. Neutralize the removed fluid with baking soda (sodium bicarbonate), then flush it away with a large amount of water or consult your Komatsu distributor or battery maker. 3. After adding distilled water, tighten cap (1) securely. Electric eye inclicator Check the condition of battery with indicator. The working condition of battery can be judged by the e lectric eye indicator on the upper surface of battery.
Under normal condition, the electric eye indicator indicates blue. If the electri c eye indicator indicates white or red, it means the battery is under the condition of lack of electricity or elec- trohlyte, and need to change electricity or add ele c trolyte immediately. 4-52