ATTACHMENTS AND OPTIONS MACHINES READY FOR ATTACHMENTS HYDRAULIC CIRCUIT NOTICE When a breaker is installed, it is necessary to connect the return circuit directly to the return filter, so use only B mode. Do not use any other mode. The standard set pressure of the service valve safety valve depends on the mode selected when the machine is shipped from the factory. If B mode is selected: 20.6 MPa (210 kgf/cm 2 , 2980 PSI) If A or E mode is selected: 27.4 MPa (280 kgf/cm 2 , 3980 PSI) Adjustment may be needed depending on the attachment, so in such a case, please contact your Komatsu distributor.
SWITCHING HYDRAULIC CIRCUIT Depending on the type of attachment, set the working mode on the monitor as follows. The set pressure of the service valve safety valve and the hydraulic circuit switch is according to the working mode selected. ADJUSTING OIL FLOW Depending on the attachment, it is necessary to change the oil flow in the service circuit. For details of setting the oil flow, see "OPERATION (PAGE 6-15)". SWITCHING BETWEEN BREAKER AND GENERAL ATTACHMENT When a possible attachment (if equipped) is installed and B mode is selected: 1) The circuit becomes a circuit for breaker operation (1-way circuit).
2) The hydraulic oil flowing in the breaker circuit flows to the additional filter for the breaker. 3) The relief valve is set to a lower pressure. When shipped from factory: 20.6 MPa (210 kgf/cm 2 , 2980 PSI) 4) It is possible to adjust the maximum flow with the select mode. When a possible attachment (if equipped) is installed and A mode or E mode is selected: 1) The circuit becomes a circuit for crusher operation (2-way circuit). 2) The hydraulic oil flowing in the crusher circuit does not flow to the additional filter for the breaker. 3) The relief valve is set to a higher pressure. When shipped from factory:
27.4 MPa (280 kgf/cm 2 , 3980 PSI) 4) It is possible to adjust the maximum flow with the select mode. 6-9 Attachment Working mode Hydraulic circuit Set pressure of service safety valve Breaker or other attachment with one-way circuit B mode Return circuit automatically switched so that it does not pass through control valve When shipped from factory : 20.6 MPa (210 kgf/cm2, 2980 PSI) Crusher or other attachment with two-way circuit A mode or E mode Return circuit automatically switched so that it passes through control valve When shipped from factory : 27.4 MPa (280 kgf/cm2, 3980 PSI)