Komatsu — ACCUMULATOR

MACHINES READY FOR ATTACHMENTS ATTACHMENTS AND OPTIONS ADDITIONAL FILTER FOR BREAKER This filter (5) prevents deterioration of the hydraulic oil when using a breaker. Oil only flows when B mode is selected on the monitor. NOTICE Always install an additional filter in the return circuit on machines equipped with a hydraulic breaker. ACCUMULATOR The accumulator is charged with high-pressure nitrogen gas, so it is extremely dangerous if it is handled incor- rectly. For details of handling, see “HANDLING ACCUMULATOR (PAGE 3-56)”. WARNING This accumulator (6) is installed to reduce the peak pressure in the hydraulic circuit when a breaker is used. Normally, do not touch it.

NOTICE The need to install an accumulator depends on the breaker manufacturer. When installing a breaker made by another manufacturer, please consult your Komatsu distributor. Depending on the breaker manufacturer, it may be neces- sary to install the accumulator at the inlet or outlet port of the breaker. 6-8