Steering 46 NOTICE Improper installation may cause moisture and contaminants to enter the gear, which may result in severe damage. A 12. Install the new bellows on the gear. Ensure the bellows are seated properly on the gear housing and inner tie rods. 13. Rotate the bellows back and forth approximately 15 degrees to evenly disperse the sealant be- tween the bellows and the gear housing. 05/30/2012 f462241 B 14. Install new Oetiker clamps on each of the bel- lows as follows. A. Do not apply Terostat near the small end of the bellows. B. Only apply Terostat to the gear where the large end of the bellows seats. NOTICE Fig.

7, Apply Terostat To Large End of Bellows Fully opening an Oetiker clamp may cause perma- nent damage and render it ineffective. 14.1 Rotate the ears of the large Oetiker clamp forward on the bellows to avoid pinching the clamp in the next step. 14.2 Ensure the large Oetiker clamp is prop- erly seated in the clamp groove on the bellows. Align the large Oetiker clamp ear with the small clamp ear. Both clamp ears should be aligned with the rack housing casting rib. See Fig. 9 . 3 1 2 4 5 09/09/2009 f462176 1. Inner Tie Rod 2. Small Oetiker Clamp 3. Bellows 4. Large Oetiker Clamp 5.

Housing Casting Rib 11/30/2011 f462214 Evenly apply a bead of Terostat MS 939 sealant where the large ends of the bellows seat on the gear housing. Fig. 9, Oetiker Clamp Alignment Fig. 8, Terostat MS 939 Sealant Application Century Class Trucks Maintenance Manual, January 2016 46/7