Pilot Pump The construction of the pilot pump section is the same as pump sections one and two, except that there are no inserts (9, Figure 7-3) in the pilot pump. In the pilot pump, pressurized fluid is directed between the rotor (1, Figure 7-4) and the vane (8). Pump Removal 1. Match mark the hoses and lines so that they can be returned to their original positions at the time of assembly. 2. Disconnect hoses (1, Figure 7-5), (2), and (3) from the pump. 1. Rotor 2. Cam Ring 3. Outlet 4. Passage 5. Inlet 6. Inlet 7. Outlet 8. Vanes 1. Inlet Hose 2. Outlet Hose 3. Hose A-G Positions of Vanes Pump Discharge Oil Pump Inlet Oil FIGURE 7-5 4037 3.
Disconnect hose (4, Figure 7-6) from the pilot pump section. 4. Pilot Pump Hoses FIGURE 7-4 4036 FIGURE 7-6 4038 7-4 HYDRAULIC SYSTEM Mega 300-III Shop Manual