Cylinder Operation Oil flow from the pump (1, Figure 7-78) can enter cylinder port A or port B depending on the position selected at the control valve. When pump flow enters port A, the flow pushes the piston (2) down the tube. This extends the cylinder rod (3) out of the cylinder. Oil from the rod side of the cylinder flows out of port B and back to the reservoir (4). The force generated when the rod is extended, can be calculated as follows.
F 2 = P x π (D 2 - R 2 ) 4 Where F 2 = Force, P = Pressure, π = 3.14, D = Cylinder Inside Diameter, R = Rod Diameter Because the rod (3, Figure 7-78) takes up space inside the cylinder, the rod side of the cylinder fills faster than the opposite side of the cylinder. This causes the rod (3) to retract faster than it extends. The quantity of oil (Q1) needed to fully extend the cylinder, and the quantity (Q2) needed to fully retract the cylinder can be calculated as follows. See Figure 7-79. 1. Pump 2. Piston 3. Cylinder Rod 4. Reservoir A. Port A B. Port B D. Cylinder Inside Diameter F 1 . Cylinder Extend Force R. Rod Diameter S.
Stroke Length FIGURE 7-79 4113 Q 1 = S x π D 2 Q 2 = S x π (D 2 - R 2 ) 4 4 Q 1 > Q 2 FIGURE 7-78 4112 Where Q 1 = Quantity of Oil needed to Fully Extend, Q 2 = Quantity of Oil needed to Fully Retract, π = 3.14, D = Cylinder Inside Diameter, R = Rod Diameter, S = Stroke Length F 1 = P x π D 2 4 Where F 1 = Force, P = Pressure, π = 3.14, D = Cylinder Inside Diameter When pump flow enters port B, the flow fills the rod (3, Figure 7-78) side of the cylinder and pushes the piston (2) down the tube. This retracts the cylinder rod (3). Oil from the other side of the piston (2) is forced out port A and back to the reservoir (4).
The force generated when the rod is retracted, is less than the force generated when the rod is extended. This is true because the piston (2) area that is acted on by the oil pressure is smaller on the rod (3) side of the piston (2) than on the opposite side of the piston (2). The force generated when the rod (3) is retracted can be calculated as follows. 7-28 HYDRAULIC SYSTEM Mega 300-III Shop Manual