Engine Start Circuit When the ignition switch (1, Figure 9-1) is turned to START, terminal BR of (1) is energized and this conducts current to terminal BR of battery relay (2). This closes the contacts of (2) and this connects the batteries to terminal 30 of starter (3) and terminal B of start relay (4). When the ignition switch (1) is turned to the START position, current flows from terminal C of the starter switch to terminal C of the start relay (4). Current then flows through the start relay coil and out terminal D, on to the starter controller (5) terminal S and out terminal E to ground. This closes the contact in the start relay (4).
This directs current flow from terminal PP of (4) to terminal 50 of the starter (3), and this causes the starter to rotate and crank the engine. The engine can be cranked only when the gear select switch (6) is in the NEUTRAL position. If the gear select switch (6) is in FORWARD or REVERSE, the current that flows from the switch (6) to the starter controller (5) opens the path to ground for the start relay (4). This prevents the start relay (4) from closing. When the alternator is being driven, terminal R of the alternator (8, Figure 9-1) sends a square wave signal to terminal P of the starter controller (5). The size of the signal is directly related to the speed of the alternator.
When the alternator reaches a speed of 500 RPM, the signal to the controller (5) causes it to create an open in the circuit between terminals S and E inside the controller (5). This causes an open in the ground path for current that powers the start relay (4). This opens the contact in the start relay (4) and prevents the starter (3) from cranking. The square wave signal prevents the engine from driving the starter motor if the key is held in the START position after the engine starts. The square wave signal also prevents the starter motor from being damaged if the start key is turned to start when the engine is running. 9-2 ELECTRICAL SYSTEM Mega 300-III Shop Manual