OPERATION 3.17 FIRE DETECTION AND SUPPRESSION SYSTEM 3.17.4 INDICATION OF OPERATIONAL MODES AT CONTROL MODULE, AFTER AUTOMATIC ACTUATION OF THE FIRE SUPPRESSION SYSTEM Alarm to Shutdown Period - The RED alarm LED and the audio alarm will pulse at a rate of 2 times per second. Shutdown to Discharge Period - The RED alarm LED and the audio alarm pulses "on" four times per second. Timer Setting (factory adjustment) G Alarm to Shutdown: 5 seconds G Shutdown to Discharge: 10 seconds In Case of Fire G Act according to the circumstances and the applying safety regulations.
G Evacuate area to lessen risk of injury from flames, heat, hazardous vapours, explosions, or other hazards that may be created. G Evacuate endangered Persons. G Inform the fire brigade. G Fight the fire. For continued protection, the Detection and Actuation Sys- tem and the Fire Suppression System must be recharged through authorized Service Personnel immediately after operation. 253 WARNING CAUTION