Komatsu — 24.11 WHEN REQUIRED

24. SERVICE PROCEDURE The lighting and horn circuits are protected by an automatic reset circuit breaker (1). A 20 amp circuit breaker is mounted on the underside of the instrument panel. In the event of a short circuit or ground, the circuit breaker will open and close until the trouble clears or is corrected. The circuit breaker will then return to and stay in its normal closed position. It is important to use the same capacity circuit breaker for replacement. To install a new circuit breaker, remove the instrument panel and pull from housing. Retain nuts and remove the two screws (panel face) securing the circuit breaker. Disconnect the wiring and replace with a new circuit breaker.

24.11.2.4 CIRCUIT BREAKERS The starting and ether circuits are protected by an automatic reset circuit breaker (2). A 20 amp circuit breaker is mounted on the underside of the instrument panel. In the event of a short circuit or ground, the circuit breaker will open and close until the trouble clears or is corrected. The circuit breaker will then return to and stay in its normal closed position. It is important to use the same capacity circuit breaker for replacement. To install a new circuit breaker, remove the instrument panel and pull from housing. Retain nuts and remove the two screws (panel face) securing the circuit breaker. Disconnect the wiring and replace with a new circuit breaker.

The back up alarm, fuel gauge, gear range indicator, gauge cluster lamps, and engine shut down solenoid circuits are protected by an automatic reset circuit breaker (3). A 6 amp circuit breaker is mounted on the underside of the instrument panel. In the event of a short circuit or ground, the circuit breaker will open and close until the trouble clears or is corrected. The circuit breaker will then return to and stay in its normal closed position. It is important to use the same capacity circuit breaker for replacement. To install a new circuit breaker, remove the instrument panel and pull from housing. Retain nuts and remove the two screws (panel face) securing the circuit breaker.

Disconnect the wiring and replace with a new circuit breaker. REMARK Under the inside mounting screw nut on the 6 amp circuit breaker there are a pair of two ground wire connectors. 24.11.2.5 BATTERY 24.11.2.5.1 General A WARNING 1 A battery gives off highly flammable gas. Never allow sparks, open flame or lighted smoking material near the battery. Avoid spilling any electrolyte on hands or clothing. Always wear safety glasses when working on a battery. When using a booster battery and jumper cables, connect the negative (ground) cable to the machine’s frame, away from the battery. Always connect the ground cable last and disconnect it first to avoid sparks near the battery.

A spark could cause a battery explosion and injury. Never check the battery charge by placing a metal object across the terminals. The sparks could cause a battery explosion. Use a voltmeter or hydrometer to measure charge. Be sure the electrical system master switch is off when connecting or disconnecting the battery to minimize the chance of sparks and explosion. The machine is equipped with one 12 volt battery. It is located in the battery box. Never allow a battery to stand on concrete, ground or a metal support unless proper insulation is provided. A wooden platform or board is sufficient insulation. Be sure the battery is fastened securely to avoid damage from vibration. 3-58