Komatsu — Cooling Fan Auto-Reverse Rotation Switch

Variable Shift Control Switch OPERATION When the speed range is in 1st, it is possible to use the variable shift control switch (3) to set the maximum speed. Turn the dial to the right to increase the setting; turn it to the left to decrease the setting. The conditions for use may differ according to the condition of the road surface. Quick Coupler Attachment Switch (if equipped) Use the quick coupler attachment switch (4) when installing or removing the attachment, or when connecting or releasing the attachment and coupler. Position (a): Release Push the switch in this position (a), then pull lock (A) in the direction of the arrow (c) and release the connection. Position (b):

Connect Cooling Fan Auto-Reverse Rotation Switch Use the cooling fan 3-position, rocker switch (5) to rotate the cooling fan in the reverse direction when cleaning the radiator. Since this is a spring-loaded switch, when it is set to ON, the switch returns to the neutral position (c) when the switch is released. It is not necessary for the operator to hold the switch in the ON position. Run the engine at idling when operating the switch. Position (a): Auto-reverse rotation function ON The fan automatically rotates in reverse for two minutes every two hours. The pilot lamp inside the switch and the cooling fan reverse rotation pilot lamp on the machine monitor light up. Position (b):

Manual reverse rotation switch ON When the fan is rotating in the normal direction and the switch is pressed once for more than 0.5 second, the fan rotates in reverse; if the switch is pressed again for more than 0.5 second, the fan rotates in the normal direction. When the fan is rotating in the reverse direction, the cooling fan reverse rotation pilot lamp on the machine monitor illuminates. When the switch is pressed, the fan continues to rotate in the reverse rotation for approximately 10 minutes. For details about cleaning the fan, see “Clean Radiator Fins and Cooler Fins” on page 3-39.

When operating the manual reverse rotation switch, press position (b) of the switch for more than 0.5 seconds and check that the cooling fan reverse rotation pilot lamp on the machine monitor flashes. Position (c): Normal (OFF) The cooling fan is constantly set to normal rotation. WA250-6 2-45 Installed Tire Max. Speed [km/h (mph)] Standard tire (20.5-25) 4.0 – 13.0 (2.5 – 8.1) Small diameter tire (17.5-25) 3.6 – 11.7 (2.2 – 7.3)