OPERATION Switching from Normal Rotation to Reverse Rotation The fan will switch from normal rotation to reverse rotation only if all the following conditions are fulfilled. If all the conditions are not fulfilled, the fan direction will not change. Conditions: The cooling fan automatic reverse rotation switch is pressed at position (a). The engine water temperature is less than 102°C (215.6°F). The HST oil temperature is above 30°C (86°F) and below 100°C (212°F). The boost temperature is below 70°C (158°F). At least 30 seconds have passed since the engine was started. The set time for switching has passed.
If the direction is switched, the cooling fan reverse rotation pilot lamp on the machine monitor will change from flashing and will stay illuminated. If the direction is not switched, the cooling fan reverse rotation pilot lamp on the machine monitor will change from OFF to flashing and will continue to flash. Switching from Reverse Rotation to Normal Rotation The fan will switch from reverse rotation to normal rotation if both of the following conditions are fulfilled. If neither of the conditions are fulfilled, the fan direction will not change. Conditions:
When the cooling fan automatic reverse rotation switch is set to any position other than portion (a) when the fan is rotating in reverse, and the HST oil temperature is above 20°C (68°F) (the temperature where the indicator of the HST oil temperature gauge starts to move from the bottom point). Fan auto reverse rotation has continued intermittently and the HST oil temperature is above 20°C (68°C) (the temperature where the indicator of the HST oil temperature gauge starts to move from the bottom point). If the direction is switched, the cooling fan reverse rotation pilot lamp on the machine monitor will change in this manner: Lighted up flashing OFF.
If the direction is not switched, the cooling fan reverse rotation pilot lamp on the machine monitor will change from being illuminated to flashing and will continue to flash. 2-48 WA250-6