Komatsu — Cooling Fan Auto-Reverse Rotation Switch

Switching from Reverse Rotation to Normal Rotation OPERATION The fan will switch from reverse rotation to normal rotation if any of the following conditions are fulfilled. If none of the conditions are fulfilled, the fan direction will not change. If the HST oil temperature is above 20°C (68°F), the following engine speed conditions do not apply. Conditions: More than 10 minutes have passed after the fan started to rotate in reverse and the engine speed has dropped to less than 1,200 rpm. When portion (a) of the cooling fan automatic reverse rotation switch is pressed again when the fan is rotating in reverse, and the engine speed has dropped to less than 1,200 rpm.

If the direction is switched, the cooling fan reverse rotation pilot lamp on the machine monitor will change in this manner: Lighted up flashing OFF. If the direction is not switched, the cooling fan reverse rotation pilot lamp on the machine monitor will change from being illuminated to flashing and will continue to flash. Using Automatic Reverse Rotation Function The fan automatically switches from normal rotation to reverse rotation and from reverse rotation to normal rotation according to the programmed time intervals. This allows the wheel loader to have the optimum heat balance (cooling). The automatic reverse mode is factory-programmed with a default time interval.

When activated, the fan reverses every two SMR (service meter reading) hours for two minutes. The ability to modify both the reverse time interval and the amount of time the fan rotates in reverse is described in the Shop Manual . Reversing interval information: The heat balance (cooling) of the wheel loader is extremely important to ensure that the machine operates to its maximum ability within the design criteria. To make sure this is possible, the hydraulic-driven cooling fan has an operating temperature range that it must work in.

If the wheel loader is outside of these parameters then the reversing fan function (both manual and automatic reverse) will not occur until the wheel loader gets within these parameters. If the reversing happens when the machine is at low idle, it will not automatically spin at full speed in the reverse direction. To spin at full speed, the operator must take the machine to high idle. WA250-6 2-47 Fan Reverse Interval Reverse Rotation Time Factory Setting 2 hr 2 min Adjustment Range 0.1 hr to 200 hr 0.5 min to 10 min