Komatsu — Measuring Bucket Dump Angle

OPERATION 7. Set the work equipment lock lever (4) to the LOCK position to lock the work equipment control lever. 8. Turn the key in the starting switch to the OFF position (A) and remove the key. 9. Read the inclinometer and record the bucket dump angle. Read the measurement while facing the left side of the machine. Measure the dump angle of a bucket with a Komatsu- approved bucket only. Dump angle: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50 degrees 2-134 WA250-6