Komatsu — Measuring Coupler Dump Angle

Measuring Coupler Dump Angle OPERATION Required Inclinometer 1. Park the machine on level ground and check the surface flatness. Open the cab door and place the inclinometer on the cab floor. The reading must be 0 degrees. 2. Check that the tire pressure is the same for all four tires. The pressure must be within specification for the tires. See “Tire Pressure” on page 2-143. 3. Raise the coupler about one foot from the ground. Remark When the bucket is parallel with the ground, the coupler dump angle is 90 degrees. 4. Place the inclinometer on the coupler at the location indicated by the arrow in the graphic.

This is the only location to place the inclinometer where you can get a reasonably accurate coupler dump angle measurement. 5. Move the work equipment control lever to the RAISE position (a) and lift the boom to its maximum height. You can only measure the coupler dump angle with the boom at maximum height. Make sure that the lift arm control lever is at the HOLD position (b) once the boom is at maximum height. 6. Use the work equipment control lever and tilt the coupler to the DUMP position (f). You can only measure the coupler dump angle with the coupler at maximum dump angle. Make sure that the work equipment control lever is at the HOLD position (b) once the coupler tilts. WA250-6 2-135