Komatsu — Clean Inside of Cooling System

The mixing ratio depends on the ambient temperature, but it should always be a minimum of 30% by volume (amount of antifreeze/total amount of coolant in system x 100). MAINTENANCE The freezing temperature of 100% undiluted Supercoolant is -15 ° C (5 ° F). Do not store undiluted Supercoolant at a temperature below -15 ° C (5 ° F). Water and Supercoolant Mix Ratio Table Antifreeze coolant is flammable. Keep it away from flame. Antifreeze coolant is toxic. When removing the drain plug, be careful not to get water containing antifreeze coolant on yourself. If antifreeze gets in your eyes, flush your eyes with a large amount of fresh water and see a doctor immediately.

Stop the machine on a level surface. Required Suitable water: To dilute the antifreeze; for details, see “Coolant and Water for Dilution” on page 3-6. Antifreeze density gauge: To control the mixing proportions. Container: To catch the drained coolant; capacity must be larger than the specified coolant volume. Hose: To fill the machine with coolant and water. 1. Stop the engine. 2. Check that the coolant temperature has gone down enough to make it possible to touch the radiator cap surface by hand, then turn radiator cap (1) slowly until it contacts the stopper to release the pressure. 3. Push radiator cap (1); turn it until it contacts the stopper; then remove it. WA250-6 3-31 Min.

atmospheric temperature °C Above -10 -15 -20 -25 -30 °F Above 14 5 -4 -13 -22 Amount of antifreeze liter 6.6 7.8 9.0 10.1 11.0 US gal 1.74 2.06 2.38 2.67 2.91 Amount of water liter 15.4 14.2 13.0 11.9 11.0 US gal 4.07 3.75 3.43 3.14 2.91 Volume ratio % 30 36 41 46 50