Komatsu — Clean Radiator Fins and Cooler Fins

MAINTENANCE Using Compressed Air Steam or water can be used to clean the fins instead of compressed air. Before opening the fan guard, stop the engine. Hang a warning tag on the work equipment control lever. Cleaning with Rear Grill Open 1. Stop the engine. 2. Open rear grill (1). 3. Remove bolts (3) and open fan guard (2). 4. Use compressed air to blow out any mud, dirt, or leaves clogging radiator fins (4). It is possible to use steam or water in place of compressed air. Remark If the steam jet nozzle is brought too close to the radiator fins, it may damage the fins. Keep the nozzle a suitable distance away from the fins when cleaning. 5. Work under the following rough conditions.

Injection pressure: . . . . . . . . . . . . . . . . . . Max. 9.8 MPa (1420 psi) Nozzle diameter: . . . . . . . . . . . . . . . . . . . . . . . .Max. 2 mm (0.1 in) Distance between nozzle and radiator fins: . . Min. 100 mm (3.9 in) 6. Check the rubber hose. Replace with a new one if the hose has cracks or is hardened by aging. 7. Check hose clamps for looseness. 8. After cleaning, close fan guard (2) and install bolts (3). 3-42 WA250-6