Komatsu — Replace Slow-Blow Fuse

MAINTENANCE Replace Slow-Blow Fuse Remark Always turn the power OFF when replacing the slow-blow fuse (turn the starting switch to the OFF position). Always replace the slow-blow fuse with one of the same capacity. The slow-blow fuse box (2) is at the side of the engine, on the left side of the machine. 1. Turn the starting switch to the OFF position (A). 2. Remove the slow-blow fuse box from the chassis. There are three slow-blow fuses. 3. Open covers (1), (2), and (3) of the slow-blow fuse box. Covers (2) and (3) can be removed easily by using protrusion (A) on the body as a fulcrum and levering the catch of the cover with a flat-headed screwdriver to release it. 4.

Loosen screws (4) and (5) and remove them. When screws (4) and (5) are removed, slow-blow fuse (6) will also come off, together with electric wiring (7) and (8). 5. Using screws (4) and (5), install a new slow-blow fuse together with electric wiring (7) and (8) in the slow-blow fuse box; then close covers (1), (2), and (3). 6. Install the slow-blow fuse box to the chassis. For more information about the slow-blow fuses, see “Slow-Blow Fuse” on page 2-72. 3-50 WA250-6 (A) 80A Chassis power source (B) 120A Engine preheating power source (C) 50A Battery power source (starting, hazard)