Komatsu — AFTER COLD WEATHER

. OPERATION COLD WEATHER OPERATION BATTERY WARNING AFTER COMPLETION OF WORK The undercarriage, belt conveyor and feeder may be frozen due to mud and water on them, hindering the engine from starting up the next morning. To prevent such a trouble, observe the following. Remove the mud and water on the machine. Park the machine on the hard and dry ground. If a ground of such conditions is not available, place wooden boards on the ground and park the machine on them. That practice will prevent the undercarriage from being frozen, keeping it off the ground, and the machine can Open the drain valve and drain any water collected in the fuel system to prevent it from freezing.

As the battery capacity drastically drops in low temperatures, cover or remove the battery from the machine, store the battery in a warm place, and install it again the next morning. If the electrolyte level is low, add distilled water in the morning before beginning work. Do not add water after the day's work to prevent diluted electrolyte in the battery from freezing during the night. The machine can be protected from fast cooling down during the night time either by parking it in a garage or covering it with tarpaulin. Disconnect the hose from the water sprinkler nozzle or drain all water in it. AFTER COLD WEATHER When the season changes and the weather becomes warmer, do as follows.

Replace the fuel and oil for all parts with oil of the viscosity specified. For details, see "RECOMMENDED FUEL, COOLANT AND LUBRICANTS (PAGE 4-13)". 3 - 131 To avoid gas explosions, do not b ring fir e or sparks near the battery. Battery electrolyte is dangerous. I f it gets in y our eyes or on y our s kin, wash it off with large amounts o f water, and consult a doctor. When the ambient temperature drops, the capacit y of th e battery will also drop . If the battery charge ratio is low, the batter y electrolyte may f reeze . Maintain the battery charge as close as possible to 100%. Insulate it against cold temperature to ensur e the machine ca n be started easily the next morning .

REMARK Measure t he specific gravit y and calculate the charging r ate f rom the following conversion table. Electrolyte Temperature (°C) Charging Rate (%) 20 0 -10 -20 100 1.28 1.29 1.30 1.31 90 1.26 1.27 1.28 1.29 80 1.24 1.25 1.26 1.27 75 1.23 1.24 1.25 1.26