Komatsu — 3.5.3 VENTILATION AND HEATING

GUARDS, CAB AND DRIVER’S SEAT 3.5.3 VENTILATION AND HEATING The ventilation and heating of the cab serve to reduce the operator’s stress both in summer and in winter; these functions also serve to eliminate condensate from the front window, thus ensuring visibility during both work and travel. Ventilation and air change are achieved by means of a 3-speed fan, which is assembled on the outside of the machine, under the cab, and is operated with a selector (3).

The air suction is protected by a filter positioned on the right side of the cab, while air distribution is obtained through a series of adjustable vents with variable flow rate (1) for the side flows or through the vents (2) for the flows that serve to defrost and defog the front window. A radiator having the function to heat the air conveyed into the cab is installed beside the fan; this is used in the cold season and receives the hot water necessary for the heat exchange directly from the engine cooling circuit. The water supply flow is partialized or excluded by means of a cock operated by the knob (4).

The intensity of the hot water flow can be increased by turning the knob (4) clockwise. NOTE q If the operator deems it necessary, the machine can be equipped with air conditioning system in addition to the ventilation and heating system. This is particularly useful in the hot season, when the temperatures are rather high. For further information on the use of the air conditioning system, see "3.5.4 AIR CONDITIONER (if installed)". 125