Komatsu — 4.8.2.b CHANGING THE HYDRAULIC OIL

MAINTENANCE PROCEDURES 4.8.2 MAINTENANCE INTERVALS IN CASE OF USE OF THE DEMOLITION HAMMER In machines equipped with demolition hammer hydraulic oil deteriorates more rapidly than in machines used for simple digging operations. When using the demolition hammer, always keep to the following maintenance plan. 4.8.2.a CHANGING THE HYDRAULIC OIL FILTER In new machines, change the filter after the first 100ч150 hours of operation and for the successive changes keep to the indications given in the table on the right. If the machine contains synthetic biodegradable oil type HEES, the filter must be changed after the first 50 hours of operation.

Replacement interval for hydraulic oil 2000 4.8.2.b CHANGING THE HYDRAULIC OIL Replacement interval (H) 1500 Change the hydraulic oil in the tank according to the intervals indicated in the table on the right. On machines containing synthetic biodegradable oil type HEES, change the oil after the first 500 hours of operation and for the successive changes keep to the indications given in the table on the right. 1000 500 0 20 40 60 80 100 Breaker operating ratio (%) RWA10900 200 Replacement interval for element