Komatsu — 4.8.12.a CHANGING THE HYDRAULIC OIL AND CLEANING THE INTAKE FILTER

MAINTENANCE PROCEDURES 4.8.12 MAINTENANCE EVERY 2000 HOURS OF OPERATION Carry out these operations together with those to be performed every 50, 250, 500 and 1000 HOURS. 4.8.12.a CHANGING THE HYDRAULIC OIL AND CLEANING THE INTAKE FILTER q On machines containing synthetic biodegradable hydraulic oil type HEES, this must be changed after the first 500 hours of operation and successively every 2000 hours, and in any case at least once a year.

q After stopping the engine, with the machine in the correct position for the performance of maintenance operations, eliminate the residual pressure from the equipment (by moving the controls more than once) and from the tank (by slowly loosening the filler cap). q Let the oil cool down until it reaches 40–45°C before carrying out this maintenance operation. q If any oil has been spilled, wipe it up immediately, in order to prevent the surface from getting slippery. q Oils, filters, the coolant and the battery are considered special waste and must be collected and disposed of according to the regulations in force.

1 - Open the engine hood (see "3.5.1 ENGINE HOOD") and slowly loosen the filler cap (1) to release any residual pressure from the tank, then remove it. 2 - Remove the drain plug (2) and let the oil flow out, gathering it into a container with suitable capacity. Use a 41 mm wrench. 3 - Remove the plug (3) positioned on the hydraulic pump intake flange and let the oil flow out, gathering it into a container with suitable capacity. Use a 27 mm wrench. 4 - Loosen the clamps and disconnect the intake coupling (4). 5 - Loosen and remove the screws (5) and remove the flange (6) complete with gasket (7) and filter (8).

6 - Clean the filter (8) using light solvents (kerosene, diesel oil, etc.); dry the filter with low-pressure compressed air (max. 3 bars). IMPORTANTE q Carefully check the filtering element grid and if it is not in perfect conditions, change it. 7 - Position the gasket (7) and put back the flange (6) complete with filter (8). 8 - Connect the intake coupling (4) and secure it with the clamps. 228 ATTENZIONE AVVERTENZA