Perkins — Perkins Sabre Marine Engines Installation Manual

TPD1317e Chapter 7 7.6 Battery and Starter Cables (a) Batteries There are two methods by which battery performance is commonly stated:- BS3911 uses the current which can be maintained for 60 seconds, without the voltage of a nominal 12V battery dropping below 8.4 volts, whilst at a temperature of -18 o C. SAE J537 is similar except that the current is only maintained for 30 seconds and the voltage is allowed to fall to 7.2 volts. Note: Where starting at temperatures below freezing is an important requirement, a 24 volt system is the preferred choice.

(b) Starter Cables * The length of all cables in the starter circuit (whether positive or negative), should be added together to give the ‘Total Length’ Page 51 Model Batteries for temperatures down to -5oC (23oF) 12 Volt 24 Volt M300Ti M265Ti M225Ti M215C M185C One battery - 520 Amps BS3911 or 800 Amps SAE J537 Two 12V batteries in series - each 315 Amps BS3911 or 535 Amps SAE J537 M135 M130C Two 12V batteries in parallel - each 315 Amps BS3911 or 535 Amps SAE J537 M115T M92B One battery - 520 Amps BS3911 or 800 Amps SAE J537 Two 12V batteries in series - each 440 Amps BS3911 Batteries for temperatures down to -15oC (5oF) M300Ti M265Ti M115T M92 Two 12V batteries in parallel, each 520 Amps BS3911 or 800 Amps SAE J537 Two 12V batteries in series, each 520 Amps BS3911 or 800 Amps SAE J537 M225Ti M215C M185C M135 M130C Two 12V batteries in parallel - each 315 Amps BS3911 or 535 Amps SAE J537 Two 12V batteries in series - each 315 Amps or 535 Amps SAE J537 Starter cables for 12 or 24 volt systems *Maximum total length Cable size metric Nominal C.S.A.

Nominal resistance in ohms Approx. equivalent size Metres Feet mm2 in2 Per metre Per foot English imperial America B&S SAE 5,6 19.00 61/1,13 61 0.0948 0,000293 0.0000890 61/.044 00 9,0 28.30 19/2,52 95 0.1470 0,000189 0.0000600 513/.018 000