Perkins — Perkins Sabre Marine Engines Installation Manual

Chapter 8 TPD1317e 8.4 M115T and M92 Engines Figure 2 shows the position of both the speed selector and manual stop lever on the injection pumps fitted to the M115T and M92 engines. An electric stop solenoid is provided as standard equipment, but the mechanical stop lever, which is intended for remote operation by a piano wire type cable assembly, is an alternative means of stopping the engine and it is independent of electrical supply. The manual stop lever is, therefore, a back-up control to be used in the rather remote eventuality of the failure of the electric stop to work.

It is recommended that it is connected, with the cable arranged so that it can be operated without opening the engine box (in case of fire) Gearboxes supplied at the time that the engine is purchased will be fitted with connections to suit Morse 33C cables. Speed selector Stop lever Run Stop control Viewed from above Idle Full speed M92 M115T Figure 2 - Speed selector lever and stop lever Page 58