Perkins — Perkins Sabre Marine Engines Installation Manual

Chapter 11 TPD1317e Page 78 Model M115T Model M92 Minimum cross section of air duct (per engine). 174 cm2 (27 sq ins) 139 cm2 (21.5 sq ins) temperate climates temperate climates 348 cm2 (54 sq ins) 277 cm2 (42.9 sq ins) for hot climates for hot climates Exhaust Exhaust gas flow 16.4 m3/min (579 ft3/min). 15.1 m3/min (533 ft3/min). Maximum restriction measured within(305 mm) 12” of turbocharger outlet. 10.2 kPa (3.0” Hg, 76 mm) Recommended pipe bore (wet exhaust). 88.9 mm (3.5”) 76 mm (3”) Minimum rise from sea water level to exhaust outlet centreline. 203 mm (8.0”) Lubricating System Recommended lubricating oil.

AP1 CG4, ACEA E3 Sump capacity maximum 7 litres (12.3 pints) Maximum installation angle plus planing angle for continuous operation. 20o nose up Oil pressure, in operating speed range (steady state). 3.0 to 3.7 bar (43.5 to 54 Ibf/in2) Low oil pressure switch setting. 0.8 bar (12 Ibf/in2) Electrical System Alternator (insulated) Prestolite A127 40A (24V) or 70A (12V). Starter type (earth return) Prestolite M127 - 12 volt only Starter type (insulated) Prestolite S115 - 12 volt and 24 volt Number of teeth in flywheel 126 Number of teeth on starter 10 Cold Start Limits Minimum cold start temperature (without aid).

-10oC Batteries for minimum 12 volt system - 1 off 12 volt 520 amp to BS3911 cold start 24 volt system - 2 off 12 volt 440 amp to BS3911