Operation 3.2 Explanation of components 22. Emergency steering switch This switch (22) is the manual control switch for the emergency steering. a Even when the engine has stopped, steering operations are made possible by pressing this switch. Position (a): ON The pilot lamp inside the switch and the emergency steering pilot lamp on the machine monitor light up and it becomes possi- ble to operate the steering. GK038034 When the switch is released, it automatically returns to its origi- nal position. Actuate the emergency steering only in cases of emergency or when checking the function. The time for operating the emer- gency steering continuously is a maximum of 60 seconds.
When using the emergency steering, travel at a speed of less than 5 km/h (3.1 MPH). For details, see "Emergency steering (3-126)". 23. Cooling fan reverse rotation switch a This switch (23) is used to rotate the cooling fan in the reverse direction when cleaning the radiator. Position (a): Manual reverse rotation switch ON When the fan is rotating in the normal direction, if the switch is pressed once, the fan will rotate in reverse; if the switch is pressed again, the fan will rotate in the normal direction. When the fan is rotating in the reverse direction, the cooling fan reverse rotation pilot lamp on the machine monitor lights up.
For details, see "Clean radiator fins and cooler fins (4-43)". GK038035 Run the engine at idling when operating the switch. REMARK When the direction of rotation of the fan switches, the reverse rotation pilot lamp flashes. WA470-6H – VEAM946100 3-53