Komatsu — 3.2.2 Switches

3.2 Explanation of components Operation 23. Cooling fan auto reverse rotation switch (Option) b b This switch (23) is used to rotate the cooling fan in the reverse direction when cleaning the radiator. c Position (a): Auto reverse rotation function ON The fan automatically rotates in reverse for 2 minutes every 2 hours. The pilot lamp inside the switch and the cooling fan reverse rotation pilot lamp on the machine monitor light up. a a a Position (b): Manual reverse rotation switch ON When the fan is rotating in the normal direction, if the switch is pressed once, the fan will rotate in reverse; if the switch is pressed again, the fan will rotate in the normal direction.

When the fan is rotating in the reverse direction, the cooling fan reverse rotation pilot lamp on the machine monitor lights up. GK038036 GK038036 For details of the procedure for cleaning, see "Clean radiator fins and cooler fins (4-43)". Position (c): Neutral (OFF) The cooling fan is constantly set to normal rotation. Run the engine at idling when operating the switch. REMARK When the direction of rotation of the fan is switched, the reverse rotation pilot lamp flashes. When the machine is operating under high load or in low tem- peratures, the direction of rotation of the fan may not change. This is to protect the machine. When the engine is stopped, the fan returns to normal rotation.

When the switch is set to position (b) (Manual reverse rotation switch ON), if the switch is released, it returns to position (c) (Neutral). Even if the switch is not kept pressed at position (b), the fan will continue to rotate in reverse direction for a certain period, so there is no need to keep the switch pressed at posi- tion (b). 3-54 WA470-6H – VEAM946100