3.2 Explanation of components Operation 5. Fresh/Recirc selector switch Use this switch (5) to switch between recirculation of the air inside the cab and intake of fresh air from outside. When this switch is pressed, recirculation of inside air is selected and (A) lights up on the display monitor. If the switch is pressed again, intake of fresh air is selected and (B) lights up on the display monitor. It changes in the order RECIRC, FRESH, RECIRC. GK038063 RECIRC: Only the air inside the cab is circulated. Use this position when it is needed to carry out quick heating or cooling of the cab, or when the outside air is dirty (smells or is dusty).
Air conditioner monitor display Condition of vents (A) RECIRC FRESH: Fresh air is taken in from the outside for normal heating or cool- ing of the cab. Use this position to make the air inside the cab fresh or to remove the mist from the cab windows. (B) FRESH When the air conditioner takes in fresh air from the outside, the pressure inside the cab rises and this prevents the entry of dirt. The higher the position of the fan switch, the more efficient this becomes. Method of operation Cooling operation 1. Press main power switch (1) of the air conditioner to turn the power ON. A 2 5 2. Press fan switch (2) and set the air flow to “Hi“. 3.
Press temperature control switch (3) and set the display monitor to COOL (A). 4 1 4. Press air conditioner switch (4) to turn the air conditioner switch ON. 3 GK038066 5. Press RECIRC/FRESH selector switch (5) to select RECIRC. 6. When the temperature inside the cab goes down, use the temperature control switch and the fan switch to set to the desired temperature. REMARK If the temperature control switch is pressed to set the display monitor to COOL (A) and the air conditioner is run with the air flow at “Lo“ for a long period, there is a slight risk that the evapo- rator will freeze.
If it freezes and no cold air comes out, turn the air conditioner switch OFF, raise the temperature setting, run the air conditioner with the air flow at “Hi “ for a short time, then turn the air condi- tioner switch ON again. 3-76 WA470-6H – VEAM946100