Komatsu — Carrying out KOWA (KOMATSU Oil Wear Analysis)

4.2 Outlines of service Maintenance Handling oil, fuel, coolant, grease and carrying out KOWA (KOMATSU Oil Wear Analysis) KOWA analysis items ! Analysis of metal wear particles This uses an ICP (Inductively Coupled Plasma) analyzer to measure the density of metal wear particles in the oil. GK032233 ! Measurement of particle quantity This uses a particle quantifier index measurement machine to measure the quantity of iron particles of 5 µ or more, enabling early detection of failures. GK032234 !

Others Measurements are made of items such as the ratio of water in the oil, density of the antifreeze coolant, ratio of fuel in the oil, and dynamic viscosity, enabling a highly precise diagno- sis of the machine's health. Oil sampling ! Sampling interval 250 hours: Engine 500 hours: Other components ! Precautions when sampling " Make sure that the oil is well mixed before sampling. " Carry out sampling regularly at fixed intervals. " Do not carry out sampling on rainy or windy days when water or dust can get into the oil. For further details of KOWA, please contact your KOMATSU dis- tributor. WA470-6H – VEAM946100 4-11