4.9 Service procedure Maintenance When required Clean inside of cooling system ! Use a ladder or stand when removing or fitting the radiator cap and when adding water. ! Immediately after the engine is stopped, the engine coolant is hot and the pressure inside the radiator is high. Removing the cap and draining the water under this condition could cause burns. Allow the engine to cool down. To loosen and remove the radiator cap, use a suitable climbing aid (for example a ladder) to climb up the back of the machine. Then turn the cap slowly to release the pressure. ! Start the engine and flush the system.
When standing up or leaving the operator's seat, set the safety lock lever to the LOCK position. ! For details of starting the engine, see "Check before starting engine, adjust (3-88)" and "Starting engine (3-105)" in the OPERATION section of the Operation and Maintenance Manual. ! When the undercover is removed, there is danger of touch- ing the fan. Never go to the rear of the machine when the engine is run- ning. Clean the inside of the cooling system, change the coolant and replace the corrosion resistor according to the table below. Permanent type antifreeze shall meet the requirements of ASTM D3306-03. Stop the machine on level ground when cleaning or changing the coolant.
The coolant has the important function of preventing corrosion as well as preventing freezing. WA470-6H – VEAM946100 4-35 WARNING WARNING Kind of coolant Cleaning inside of cooling system and changing coolant Adding corrosion resistor KOMATSU supercoolant (AF-NAC) Every two years or every 4000 hourswhichever comes first unnecessary Permanent type antifreeze (All-season type) Every year (autumn) or every 2000 hours whichever comes first. Every 1000 hoursand when clean- ing the inside of the cooling system and when changing coolant.