4.9 Service procedure When required Maintenance 4. Set a container in position to catch the drained antifreeze mixture, then open drain valve (4) under the left side of the fuel tank and drain plug (5) at the side of cylinder block, and drain the coolant. 5. After draining the coolant, close drain valve (4) and drain plug (5) and fill with city water. 6. When the radiator is full, start the engine, and run it at low idle. Keep the engine running at low idle for 10 minutes until the coolant temperature reaches more than 90°C. 7. Stop the engine, open drain valve (4) and drain plug (5), drain the water, then tighten them again. 8.
After draining the water, clean the cooling system with clean- ing agent. For the cleaning method, see the instructions for the clean- ing agent. 9. Replace the corrosion resistor cartridge, then open 2 valves (1). For details of the procedure for replacing the corrosion resis- tor, see "Replace corrosion resistor cartridge (4-76)". 10. Add coolant mixed with antifreeze until it overflows from the water filler. Decide the proportions of antifreeze and water according to the table for the mixing rate of water and antifreeze. 11. To remove the air in the cooling system, run the engine for 5 minutes at low idling, and for another 5 minutes at high adling.
(When doing this, leave the radiator cap off.) 12. Drain the coolant inside sub-tank (6), clean the inside of the sub-tank, then fill again with coolant to a point midway between the FULL and LOW marks. 13. Stop the engine, wait for approx. 3 minutes, then add coolant until the coolant level is near the coolant filler port, and tighten the cap. Check the coolant level and add coolant if necessary.. GK047031 6 GK032247 4-38 WA470-6H – VEAM946100 5 4 GK047030