4.9 Service procedure When required Maintenance Manual fan reversing method NOTE ! Never rotate the fan in reverse by hand when carrying out the operation. ! Before operating the fan reverse rotation switch, run the engine at low idling. 1. Set the directional lever to the Neutral position. 2. Set the parking brake switch to the ON position to apply the parking brake. a 3. Run the engine at low idling. 4. Press position (a) (manual reverse rotation ON) of cooling fan reverse rotation switch (1). GK038035 5. After the cooling fan reverse rotation pilot lamp on the machine monitor flashes, check that it lights up.
At the same time, “COOLING FAN REVERSE ROTATION“ is displayed on the character display and the fan is set to rotate in reverse. 6. Run the engine at high idling. Select the time for running the engine at high idling as fol- lows according to the condition of clogging. " Normal clogging: 1 to 2 minutes GK043111 " Excessive clogging: 2 to 3 minutes 7. When the cleaning is completed, run the engine at low idling. 8. Press position (a) (manual reverse rotation ON) of cooling fan reverse rotation switch (1). a GK038035 4-44 WA470-6H – VEAM946100