4.9 Service procedure Maintenance Every 250 hours service When checking electrolyte level from side of battery If it is possible to check the electrolyte level from the side of the battery, check as follows. 1. Open the cover of the battery box. There are two battery boxes: One on each side at the rear of the machine. 2. Use a wet cloth to clean the area around the electrolyte level lines and check that the electrolyte level is between the UPPER LEVEL (U.L.) and LOWER LEVEL (L.L.) lines. If the battery is wiped with a dry cloth, static electricity may cause a fire or explosion. If the battery is wiped with a dry cloth, static electricity may cause a fire or explosion.
Upper level Lower level GK032268 3. If the electrolyte level is below the midway point between the UPPER LEVEL (U.L.) and LOWER LEVEL (L.L.) lines, remove cap (1) and add distilled water to the U.L. line. 4. If distilled water has been added to any cell of cap (1), add distilled water also to the other cells. 5. Clean the vents of the battery caps, then close the caps securely. Keep the top of the battery clean and wipe it with a wet cloth. GK043081 1 REMARK If distilled water is added to above the UPPER LEVEL (U.L.) line, use a syringe to lower the level to the UPPER LEVEL (U.L.) line.
Neutralize the removed fluid with baking soda (sodium bicarbonate), then flush it away with a large amount of water or consult your KOMATSU distributor or battery maker. WA470-6H – VEAM946100 4-59