4.9 Service procedure Maintenance Every 250 hours service Check for loose wheel hub bolts, tighten If wheel hub nuts (1) are loose, tire wear will be increased and may cause accidents. 1. Check for loose nuts, and tighten if necessary. When checking for loose nuts, always turn the nuts in the direction of tightening to check. Tightening torque: 825 to 1030 Nm 2. If any stud bolt is broken, replace all the stud bolts for that wheel. Clean element in air conditioner recirculation filter 1. Loosen knob (1), then remove filter inspection cover (2). 2 GK038112 1 2. Remove filter (3) in the direction shown by the arrow. 3 3.

Use compressed air to clean the recirculated air filter in the same way as for the fresh air filter. Replace the filter with a new part if the clogging cannot be removed with compressed air, or if it has been used for 1 year. REMARK If the filter becomes clogged, the air flow will be reduced, and there will be an abnormal noise from the air conditioner unit. GK038113 WA470-6H – VEAM946100 4-65 1 GK032274