4.9 Service procedure Maintenance Every 2000 hours service 20. Next, operate the steering, bucket, and lift arm cylinders fully 3 - 4 times, then stop the engine and loosen air bleed plug (16). After bleeding the air from the hydraulic tank, tighten plug (16). Run the engine at low idling when bleeding the air. 21. Check the hydraulic oil level and add oil to the specified level. 16 For details, see "Check oil level in hydraulic tank, add oil (4-56)". GK047052 22. Next, increase the engine speed and repeat the procedure in Step 19 to bleed the air. Continue this operation until no more air comes out from plug (15). 23. After completing the air bleed operation, tighten plug (16).
Tightening torque: 11.3 ± 1.5 Nm 24. Check the hydraulic oil level and add oil to the specified level. For details, see "Check oil level in hydraulic tank, add oil (4-56)". 25. Check that there is no leakage of oil from the filter cover mount. WA470-6H – VEAM946100 4-79