Komatsu — Checking function of accumulator

4.9 Service procedure Every 2000 hours service Maintenance Checking function of accumulator For details of handling the accumulator, see "Accumulator (2-37)". PPC accumulator If the engine stops with the work equipment raised, and it is impossible to start the engine again, it is possible as an emer- gency measure to actuate the valve with the oil pressure stored in the accumulator and lower the work equipment to the ground. 1. Apply the parking brake. 2. Raise the work equipment to the maximum height, then operate the lift arm control lever to HOLD position (b). c d 3. Stop the engine. b 4. Leave the work equipment lock lever in the FREE position. a 5.

Check that the area around the machine is safe, then oper- ate the lift arm control lever to FLOAT position (d) and lower the work equipment to a point 1m above the ground. GK038040 6. When the lift arm comes to the 1 m position, return the lift arm control lever to LOWER position (c), and lower the work equipment slowly to the ground. REMARK Carry out the check within 2 minutes after stopping the engine. If the machine is left with the engine stopped, the accumulator pressure will drop and it will be impossible to check the cause of the problem. If the work equipment stops while it is moving, the gas pressure in the accumulator has probably dropped.

GK043216 Please contact your KOMATSU distributor to have the accumu- lator inspected. Replace the accumulator every 4000 hours or every 2 years. 4-84 WA470-6H – VEAM946100