Checking 1 Turn crankshaft until cam tips of No. 1 cylinder intake valve point downwards (valve closed). Caution! The engine must not be turned at the camshaft timing gear fixing bolt. Under no circumstances turn engine backwards during the measurement, otherwise considerable measuring errors result, and chain tensioner lock setbolt can spring forwards. 2 Remove rocker arm bearing support of No. 1 cylinder (05235). 3 Install intake valve rocker arm against the rigid rocker arm @la) Part No. 102 055 00 01 together with the adjustment bolt (164) Part No. 102 050 02 20 and the locknut (163) Part No. 000936 008009 (05-240). 4 Install rocker arm bearing support, 21 Nm.
5 Install the dial gauge bracket with threaded sleeve onto the stud on the front left part of the cylinder head. 6 Insert dial gauge and attach so that tip is exactly vertical on valve spring retainer with a pretension of 3 mm (small pointer on the dial gauge). Turn dial gauge clockface until large pointer is on 050906 - 21514