P-Pressure Compensator Housing Q-Orlflce R-Dlscharge Pressure S-Inlet Pressure Pressure compensator housing (P) is connected to pump inlet gallery (E), outlet gallery (M), and pump crankcase (D and J). Pressure compensator valve (L) working with the crankcase outlet valve (C) maintain discharge pressure under varying flow demands. Dis- charge pressure oil enters at point (M) and flows to center section of pressure compensator valve. At full pump stroke, as shown above, crankcase pressure is at inlet pressure. As demand for system oil decreases, discharge pressure will begin to increase, causing crankcase outlet valve (C) to close (move downward).
This blocks the pump crankcase oil (D) from the inlet gallery (E) except for any oil which passes through the crankcase orifice (Q). As system pressure approaches deadhead, pressure compensator valve (L) opens (moves downward) allowing discharge pressure oil into the crankcase. Litho in U.S.A.
110-3 CTM-7 (5-89) 2R3j 110 03 110589 RWH167 23 R70;070300 1042 150589 K-Manual Deatroke Screw L-Pressure Compensator Valve M-From Pump Outlet Gallery N-Destroke Plug or Optional Electric Destroke Solenoid O-Sprlng Full Stroke 2000 Series (PRJ-Operation and Tests PRESSURE COMPENSATOR VALVE OPERATION F-Inlet Pressure Test Port G-Dlscharge Pressure Test Port H-Helmholz Resonator (Serialized Pumps) I-Pressure Sensing Pin (Serialized Pumps) J- To Pump Crankcase The 2000 Series pump contains a pressure compensa- tor housing (P). There are two basic designs. The one shown above is for serialized pumps. Crankcase outlet valve (C) for serialized pumps uses a single spool valve design.
Non-serialized pumps have a crankcase valve operating within a fixed sleeve. Both designs function the same. A crankcase design variation within both serialized and non-serialized pumps is provided in some pump models where improved performance under high load conditions is required. In non-serialized pumps crankcase valve and outlet valve sleeve are replaced with a sleeve designed with a secondary orifice. Crankcase outlet valve (C) in serialized pumps is replaced with a fixed valve also with a secondary orifice. These variations in design allow a continuous flow of oil between pump crankcase and inlet gallery. They also require slightly more horsepower at dead- head pressure.
A-Pressure Compensator Adjusting Screw B-Sprlng C-Crankcase Outlet Valve D-From Pump Crankcase E-From Pump Inlet Gallery AllTractorManuals.com