CTM-7 (5-89) 2R3; 115 12 110589 AW1;R39624,R40193 R70;070300 1021 070388 Non-Unitized Design Unitized Design 3000 Series (HPR)-Operation and Tests 115-12 ADJUST DEADHEAD (STANDBY) PRESSURE CAUTION: Escaping fluid under pressure can penetrate the skin causing serious injury. Re- lieve pressure before disconnecting hydraulic or other lines. Tighten all connections before applying pressure. Keep hands and body away from pinholes and nozzles which eject fluids under high pressure. Use a piece of cardboard or paper to search for leaks. Do not use your hand.
If ANY fluid is injected into the skin, it must be surgically removed within a few hours by a doctor familiar with this type Injury or gangrene may result. CAUTION: When operating or testing a non- unitized designed pump without a pressure compensator spring sleeve, a relief valve, set 2070 kPa (20.7 bar) (300 psi) above deadhead pressure, MUST BE used between pump dis- charge and nearest valve (or variable restric- tion) In system. Failure to do so can result in hydraulic component or line failure which may cause personal Injury. NOTE:
When operating or testing any hydraulic pump, it is good hydraulic systems practice to include a system relief valve set at 2070 kPa (20.7 bar) (300 psi) above deadhead pressure. IMPORTANT: Adjusting screw should be set to a mini- mum depth to prevent excessive dead- head pressure at start up. 1. Install a 14 mm adapter to high pressure test port (A). 2. Connect a 0-34 500 kPa (0-345 bar) (0-5000 psi) gauge. NOTE' System pressures vary. Check applications or ma- chine manual for proper deadhead pressure setting. 3. Turn adjusting screw (C) in to increase deadhead pressure.
A-High Pressure Test Port (T1) B-Inlet Pressure Test Port (T2) C-Pressure Compensator Adjusting Screw D-Lock Nut E-Crankcase Pressure Test Port (T3) 4. Tighten lock nut (0) once deadhead pressure is set. AllTractorManuals.com Litho in U.S.A.