CTM-7 (5-89) 2R3; 010 31 110589 AW1;T85462 R70;070300 1142 080288 AW1;R39770 R70;070300 1141 260489 2000 Series (PR)-Hydraulic Pump 10-31 NOTE: Standard drive single bank pressure compensator housing is shown. Oouble bank pressure compensa- tor housing does not use packings (8) or shims (0). IMPORTANT: DO NOT install O-rings or packings If end play was out of specification, or bearing cones and cups have been replaced. Install O-rings and packlngs after correct end play Is established. NOTE: Apply a small amount of petroleum jelly to a-ring, packings and shims to hold them in place during assembly. A-o-Rlng B-Packings c-Packlngs D-Shlms 6.
Install new O-rings (C-O) and backup ring (E) on destroke plug (A) or electric destroke solenoid valve (8). IMPORTANT: Torque specification for solenoid valve (34 N'm (25 Ib-ft» Is different than de- stroke plug (61 N'm (45Ib-ft». Over torqu- Ing electric destroke solenoid may cause pump to malfunction. 7. Install destroke plug (A) or electric destroke solenoid valve (8) into housing. A-Destroke Plug B-Electrlc Destroke Solenoid C-O-Rlngs D-o-Rlngs E-Backup Rings 4. Install shims to check end play specification. 5. Install new O-rings and packings (A-C). Litho in U.S.A. AllTractorManuals.com