John Deere Radial Piston Pumps (3000 Series) — John Deere Radial Piston Pumps (3000 Series) User Manual

AW1;T86280 R70;070300 1109 070388 CTM-7 (5-89) 2R3; 010 32 110589 2000 Series (PRJ-Hydraulic Pump NOTE: Single bank pump is shown. Some double bank pumps may have a special dowel pin between the pressure compensator housing and secondary pump housing to insure proper alignment. CAUTION: DO NOT INSTALL a current design (serialized pump) pressure compensator hous- ing on an early design (non-serialized) pump or an early design pressure compensator housing (non-serialized) on a current design (serialized) pump. The mounting holes are common, but the HIGH-PRESSURE PASSAGES WILL NOT ALIGN. Failure to align the high-pressure passages will keep the pump in full stroke.

This could result in hydraulic system damage and possibly a high-pressure leak which could create a risk of personal injury. NOTE: Pressure passage location will differ between single bank and double bank pumps. They also differ between non-serialized and serialized pumps. 8. Install pressure compensator housing (C) to pump hous- ing (D) making sure system-pressure passages (A) and charge-pressure passages (8) are aligned. 9. Tighten cap screws to 70 N·m (50 Ib-ft). Continue tightening cap screws alternately to 115 N·m (85 Ib-ft). 10·32 A-System Pressure Passages B-Charge Pressure Passages C-Pressure Compensator Housing D-Pump Housing AllTractorManuals.com Litho in U.S.A.