John Deere Radial Piston Pumps (3000 Series) — John Deere Radial Piston Pumps (3000 Series) User Manual

AW1;R39774 R70;070300 1132 181287 AW1;R39776 R70;070300 1138 080288 CTM-7 (5-89) 2R3i 010 39 110589 2000 Series {PRJ-Hydraulic Pump 10-39 9. Install O-ring on crankcase outlet valve sleeve (or fixed orifice sleeve). IMPORTANT: Do not use a punch to install crankcase outlet valve sleeve (or orifice sleeve). Damage could occur to sleeve. 10. Carefully install crankcase outlet valve sleeve (or fixed orifice sleeve) through port next to adjusting screw port making sure sleeve seating surfaces are not damaged. Push sleeve against internal housing stop using a wood or brass dowel. 11. Put new O-rings on crankcase outlet valve plug (A) and plug with pin (H). 12.

Put new packings (E) on filter (F) and install filter assembly into pressure compensator housing. 13. Install shims (8), spring (C) and spring retainer (0) on crankcase outlet valve plug with pin (A). Install into housing. NOTE: DO NOT install plug with pin {HJ. Crankcase outlet valve must be adjusted. 14. Carefully install crankcase outlet valve (G) into sleeve in housing. A--crankcase Outlet Valve Plug B-Shlms C-Sprlng D-Sprlng Retainer E-Packlngs F-Fllter G--crankcase Outlet Valve H-Plug With Pin Litho in U.S.A. AllTractorManuals.com