Air Compressor Discharge Lines C8.3 Industrial Page 7-4 Section 7 - Maintenance Procedures at 500 Hours or 6 Months Maintenance Check Wear appropriate eye and face protection when using compressed air. Flying debris and dirt can cause personal injury. WARNING Shut off the engine. Open the drain valve on the wet tank to release the system air pressure. Remove the air compressor discharge line from the air compressor. Location of the air compressor discharge line can be found in Flow Diagram, Compressed Air System in System Diagrams (Section D). Measure the total carbon deposit thickness inside the air discharge line as shown.
If the total carbon deposit (X + X) exceeds 2 mm [1/16 in], clean and inspect the cylinder head, the valve assembly, and the discharge line. Replace if necessary. Contact the Cummins Authorized Repair Location for procedures. If the total carbon deposit exceeds specifications, continue checking the air discharge line connections up to the first tank until total carbon deposit is less than 2 mm [1/16 in]. Clean or replace any lines or connections that exceed this specification.