C8.3 Industrial Fuel Shutoff Valve Section A - Adjustment, Repair, and Replacement Page A-1 Fuel Shutoff Valve Preparatory Steps Label and disconnect the wiring. Remove Remove the two mounting capscrews, and remove the solenoid from the bracket. 1. Synchro-start 2. Trombetta 3. Direct link. Install NOTE: Make sure the acorn nut is tightened to be snugly on the fuel shutoff solenoid shaft (Synchro-start only ). Install the new fuel shutoff solenoid to the bracket, and connect the wires. Make sure the wiring harness one the Trombetta solenoid is installed in the six-o'clock position. Torque Value: 10 N•m [ 89 in-lb ] 1. Synchro-start 2. Trombetta 3. Direct link.
Activate the switch and check the plunger travel. Synchro- start Trombetta Direct link A = 86.8 mm [3.4 in] 91.4 mm [3.6 in] B = 60.2 mm [2.4 in] 63.5 mm [2.5 in] 117.1 mm [4.61 in] The plunger must be retracted when the fuel shutoff solenoid is activated to the RUN position B. The fuel shutoff solenoid must operate without binding.