Charge-Air Cooler C8.3 Industrial Page A-16 Section A - Adjustment, Repair, and Replacement Determine if the pressure drop is caused by a leaky charge-air cooler or a leaky connection. Spray soapy water on all hose connections, and watch for bubbles to appear at the location of the leak. If the pressure drop is caused by a leaky connection, repair the connection and repeat the test. If the leak is within the charge-air cooler, repeat the test to verify the accuracy of the pressure drop measurement. Similar pressure drop readings must be obtained in at least three consecutive tests before the reading can be considered accurate. NOTE:

If a charge-air cooler leaks more than 48 kPa [7 psi] in 15 seconds, it will appear as a major leak in a leak tank. If the pressure drop is greater than 48 kPa [7 psi] in 15 seconds, the charge-air cooler must be replaced. Refer to the OEM service manual for replacement instructions. NOTE: Charge-air coolers are not designed to be 100- percent leak free. If the pressure drop is less than 48 kPa [7 psi] in 15 seconds, then the charge-air cooler does not need to be replaced. Temperature Differential Test Install a temperature gauge in the intake manifold. Lock the fan drive in the ON mode to prevent erratic test results.

This can be done by installing a jumper across the temperature switch or supplying shop air to the fan. Refer to the OEM service manual for the lockup procedure. NOTE: Some applications have a manual switch that will lock the fan on. Operate the engine at rated rpm and load. Record the intake manifold temperature. Measure the ambient temperature at least 2 feet in front of the vehicle. The maximum temperature differential must not be greater than 25°C [77°F]. If the temperature differential is greater than 25°C [77°F], check the charge-air cooler for dirt and debris on the fins, and clean as necessary. If the problem still exists, check the cooler for internal contamination or plugging.