C8.3 Industrial Charge-Air Cooler Section A - Adjustment, Repair, and Replacement Page A-15 Install Install the charge-air cooler. Install the charge-air cooler plumbing. Refer to the OEM service manual for instructions. Pressure Test Install the pressure gauge, Part Number ST-1273, or equivalent, to the fitting in the turbocharger outlet. Install another pressure gauge, Part Number ST-1273, or equivalent, in the intake manifold. Operate the engine at rated rpm and load. Record the readings on the two gauges. If the differential pressure is greater than 21 kPa [3 psi], check the charge-air cooler for plugging. Clean or replace if necessary.
Leak Test To reduce the possibility of injury if either plug blows off during the test, secure safety chains on the test plugs to any convenient capscrew on the radiator assembly. This test must not be performed without securely fastened safety chains. WARNING To check the charge-air cooler for cracked tubes or header, remove the inlet and outlet hoses from the cooler. The charge-air cooler does not have to be removed from the chassis. Install a plug or cap over the outlet side of the cooler. Install a pressure gauge and a regulated shop air supply line with a shutoff valve to the inlet side of the cooler.
Apply air pressure to the cooler until the pressure gauge reads a steady 207 kPa [30 psi] of air pressure. Shut off the airflow to the cooler and start a stopwatch at the same time. Record the leakage at 15 seconds. If the pressure drop is 48 kPa [7 psi] or less in 15 seconds, the cooler is operational. If the pressure drop is greater than 48 kPa [7 psi] in 15 seconds, check all connections again.