Coolant Recommendations and Specifications C8.3 Industrial Page V-14 Section V - Maintenance Specifications Specifications Use a low-silicate antifreeze that meets ASTM4985 test (GM6038M specification) criteria. Concentration Antifreeze must be used in any climate for both freezing- and boiling-point protection. Cummins Inc. recommends a 50-percent concentration level (40- to 60-percent range) of ethylene glycol or propylene glycol in most climates. Antifreeze at 68-percent concentration provides the maximum freeze protection and must never be exceeded under any condition. Antifreeze protection decreases above 68 percent.
Concentration Testing Antifreeze concentration must be checked using a refractometer (such as Fleetguard® Part No. CC2800). "Floating- Ball"-type density testers or hydrometers are not accurate enough for use with heavy-duty diesel cooling systems. Coolant Change Recommendation The coolant must be drained and replaced every 2 years or 385,000 km [239,227 mi] to eliminate buildup of harmful chemicals. Cooling System Additives Supplemental Coolant Additive (SCA) Supplemental coolant additives (SCA) are recommended for all Cummins Inc. cooling systems. Antifreeze alone does not provide sufficient protection for heavy-duty diesel engines. DCA4 is the recommended SCA for all Cummins Inc. engines.
Other brands can be used if they provide adequate engine protection and do not cause seal or gasket degradation or corrosion/fouling. DCA4 SCA Concentration The recommended concentration level of DCA4 is 1.5 units for every 3.7 liters [1 gal]. The DCA4 concentration must never exceed 3.0 units for every 3.7 liters [1 gal] nor fall below 1.2 units for every 3.7 liters [1 gal]. DCA4 Filter Change Interval Supplemental coolant additives deplete during normal engine operation. Cummins Inc. recommends that the level be maintained by installation of a service coolant filter on the engine at every 10,000-km [6214 mi], 250-hours, or 3-month interval.
As noted above, the primary method is to maintain proper DCA4 concentration levels by changing the service coolant filter at every 10,000 km [6214 mi], 250 hours, or 3 months. Fleetguard® DCA4 “dipstick” test kit, Part No. CC2626, or Fleetguard® Monitor C™, Part No. CC2700, must be used if testing is deemed necessary due to one of the following reasons: DCA4 Concentration Test Addition of untreated make-up coolant in excess of 5.7 liters [6 qt] between maintenance intervals Troubleshooting of cooling system problems in the fleet (such as corrosion or seal leakage) NOTE: The practice of using a test kit to determine when to add or change the coolant filter is specifically not recommended.
No other test kit (such as Fleetguard® titration test kit, Part No. 3300846-S or 3825379-S) can be used on Cummins engines with DCA4. An optional program in some fleets to monitor SCA levels to determine if maintenance intervals are acceptable. DCA4 Unit Maintenance Guide Ethylene Glycol Propylene Glycol 40% equals -23°C [-9°F] 40% equals -21°C [-6°F] 50% equals -37°C [-35°F] 50% equals -33°C [-27°F] 60% equals -54°C [-65°F] 60% equals -49°C [-56°F] 68% equals -71°C [-96°F] 68% equals -63°C [-81°F] Fleetguard® Part No. Cummins Part No. DCA4 Units DCA4 Liquid DCA 60L 3315459 4* DCA4 Filter WF-2070 3318157 2