Cummins — 4021330

Fuel-Water Separator C8.3 Industrial Page 3-2 Section 3 - Maintenance Procedures at Daily Interval Crankcase Breather Tube Maintenance Check Inspect the breather tube for sludge, debris, or ice in the tube. Inspect the tube more frequently in icy conditions. If sludge, debris, or ice is found clean the tube with detergent and warm water or a solvent. Dry the tube with compressed air. Visually inspect the tube for cracks or damage. If damage is found, replace the crankcase breather tube. Contact your Cummins Authorized Repair Location. Fuel-Water Separator Drain Drain the water-fuel separator into a container and dispose of in accordance with local environmental regulations.

WARNING Cummins Inc. requires a fuel-water separator or fuel filter be installed in the fuel supply system. Drain the water and sediment from the separator daily.