Cummins — 4021330

C8.3 Industrial Lubricating Oil Level Section 3 - Maintenance Procedures at Daily Interval Page 3-3 Canister Type Shut off the engine. Pull up on the drain valve lever until fluid drains out of the drain tube. Drain the filter sump until clear fuel is visible. Push up on the drain valve until fluid drains out of the drain tube. Spin-on Type Shut off the engine. Use your hand to open the drain valve. Turn the valve counterclockwise approximately 3Ѕ turns until the valve drops down 25.4mm [1 in] and draining occurs. Drain the filter sump until clear fuel is visible. CAUTION When closing the drain valve, do not overtighten the valve. Overtightening can damage the threads.

To close the valve, lift the valve and turn clockwise until it is hand-tight. Lubricating Oil Level Maintenance Check Never operate the engine with oil level below the L (low) mark or above the H (high) mark. Poor engine performance or engine damage can occur. CAUTION The engine must be level when checking the oil level to make sure the measurement is correct. Shut off the engine for an accurate reading. Wait at least 15 minutes after shutting off the engine to check the oil level. This allows time for the oil to drain into the oil pan. For additional lubricating oil recommendations and oil pan capacity information, refer to Maintenance Specifications (Section V).